NotesFAQContact Us
Collection
Advanced
Search Tips
Back to results
Peer reviewed Peer reviewed
Direct linkDirect link
ERIC Number: EJ832478
Record Type: Journal
Publication Date: 2009-Mar
Pages: 2
Abstractor: As Provided
ISBN: N/A
ISSN: ISSN-0021-9584
EISSN: N/A
Construction of Ag/AgCl Reference Electrode from Used Felt-Tipped Pen Barrel for Undergraduate Laboratory
Inamdar, Shaukatali N.; Bhat, Mohsin A.; Haram, Santosh K.
Journal of Chemical Education, v86 n3 p355-356 Mar 2009
A reference electrode is one of the prerequisites of electrochemical investigations. Many electrodes are commercially available but are expensive and prone to accidental breakage by students. Here we report a simple, easy-to-fabricate, inexpensive, reliable, unbreakable, and reproducible Ag/AgCl reference electrode. The empty barrel of a felt-tipped pen is used for this purpose. The constructed electrode is similar in performance to the commercially available electrodes and has long-lasting stability. The procedure is expected to encourage undergraduate students to design their own reference electrodes for the electrochemical experiments. (Contains 2 figures.)
Division of Chemical Education of the American Chemical Society. Subscription Department, P.O. Box 1267, Bellmawr, NJ 08099-1267. Tel: 800-691-9846; Tel: 856-931-5825; Fax: 856-931-4115; e-mail: jchemed@egpp.com; Web site: http://www.jce.divched.org
Publication Type: Journal Articles; Reports - Descriptive
Education Level: Higher Education
Audience: Teachers
Language: English
Sponsor: N/A
Authoring Institution: N/A
Grant or Contract Numbers: N/A